Audit and diagnostic

























[KB796] Unlocking a temporary license
Details: In case a User has legitimately changed the system clock and is no longer able to start PcVue the following procedure can be useed to reset the dongle. THIS PROCEDURE […]
[KB1244] How to import proprietary unit trends into HDS database
I- BASIC PRINCIPLE PcVue’s proprietary archiving was not designed to interact with third-party tools. As a result, only PcVue can retrieve the information contained in such archiving units. However, there […]
[KB1245] PcVue as OPC UA server
The OPC UA gateway is used as a bridge between the PcVue OPC DA client and server and third party OPC UA clients and servers. It enables the use of PcVue as OPC UA […]
[KB1240] Influx DB provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. Common use case with InfluxDB and PcVue is IoT and BigData. With the expansion […]
[KB1243] How to configure a database transactional replication
Document attached: How to configure SQL replication SQL script attached: DBO.MSrepl_error: SQL query for trigger creation
[KB1232] Replication of two SQL Data Base
The architecture : PcVue Configuration:You can configure two databases for each instance, assigning them different names, while ensuring that the table names remain identical across both databases.Below is an example […]
[KB1242] SQL Server Native Replication (Standard edition)Template
See attached pdf document. Download attachments: KB1242.pdf
[KB1241] SQL Server Native Replication (Enterprise Edition)
See attached pdf document. Download attachments: KB1241.pdf
[KB1221] Cassandra provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. Apache Cassandra is commonly used by large organizations for applications such as social media, […]
[KB1075] How to create a sample project
To use this project, you will need to :1/ Unzip the attachment in your USR folder.2/ Rename the project according to your needs.3/ Start the project and modify the window […]
[KB1235] Oracle 21c with UDC
First, you need to download 3 installers: The server, the ADO.net provider and a GUI client for easy testing Oracle XE installation steps :– Unzip the OracleXE213_Win64.zip archive and run […]
[KB1219] EmVue v1 – Software download
Download link EmVue v1 EmVue_1.1.180.iso : Download Hash (SHA256) : 777343936F0D13EB827F55CA246AAC54FFF9074A3D9B8F72D73BD647BFB3310F How to verify the integrity of downloaded files? Prior to installing the software, it is important to check the integrity of […]
[KB1218] EmVue v1 – Release Information
Key features – An overview of the key features in version 1 Initial Release (1.0) What’s new in 1.1 – An overview of the main new features in the Release […]
[KB1237] Adding a Development station to a Multi-station Architecture
The DEV station remains passive under normal conditions but can be temporarily activated for testing purposes. Here are the steps to add a DEV station to a multi-station architecture: Configuration: […]
[KB1236] Not possible to archive in SQL database
If the traces are activated you could have this kind of error: CSchTable::AbleToWrite on ‘TRENDTABLE1′ is FALSE ID=’2’ Here’s what we recommend you check in this case: Is the database […]
[KB1233] Optimisations for SQL database archiving with HDS
1. Limit HDS traces (especially on files as they generate continuous disk access), remove Audit traces especially Ojective: Reduce the load on the system by limiting HDS traces and removing […]
[KB1231] Error loading the Application Architect configuration
This type of message appears when there are inconsistencies in the project configuration. An error message is systematically displayed in the event viewer: The error indicates the blocking point for […]
[KB1230] Protected: [Draft] How to import proprietary unit trends into HDS database
There is no excerpt because this is a protected post.
[KB1188] PcVue 16 – Software and License Utility download
[KB1228] DIMO Maint MX provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution that interacts with DIMO Maint MX and retrieves information on […]
[KB1224] Salesforce provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution to connect Salesforce Platform to PcVue to get data from CRM […]
[KB1225] Telegram provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution to Send message with emoji, bolt, italic… Send command, inline keyboards… […]
[KB1226] Twilio provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution to send an SMS from a data center or a Cloud […]
[KB1227] X provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution to create or send a tweet. Status: This provider has the […]
[KB1223] Netatmo provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution to access famous Netatmo IoT platform and Netatmo partner from PcVue. […]
[KB1222] Operat provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider is a solution to publish energy consumption in the tertiary sector from PcVue. Status: […]
[KB1220] Automatic Acknowledgment of Alarms with the Same Priority
Applies to: PcVue – Multiple versions Summary: This article explains how to modify the PARAM.DAT file, specifically the COLORWDWALARM lines, to enable automatic acknowledgment of alarms at the same level. […]
[KB1216] Sofrel OPC UA Server Validation Results
Applies to: PcVue 16.1 and later Summary: This article contains the results from validation tests of the Sofrel OPC UA Server v2.20.27 and PcVue. Originator: ELCH Details: This guide contains […]
[KB1130] HDS Files format PcVue 15
Applies to: PcVue 15 onwards Summary: This document describes the content of each HDS configuration files.Warning 1: Modifying manually these files can cause irreversible damage.Warning 2: This article is only […]
[KB1131] HDS diagnostics
Applies to: PcVue 15 onwards Summary: This article proposes different ways to diagnose proper functioning of HDS.Warning 1: Modifying manually these files can cause irreversible damage.Warning 2: This article is […]
[KB1129] HDS Files list
Applies to: PcVue 15 onwards Summary: This article lists all the files managed by the HDS.Warning 1: Modifying manually these files can cause irreversible damage.Warning 2: This article is only […]
[KB1211] How to import a local library into a PcVue project
Applies to: PcVue 12 onwards Summary: Here are the steps to import an existing library into a project. Details: To integrate an existing library into your project, you will have […]
[KB1212] How to display the networking architecture in a PcVue mimic?
Applies to: PcVue 16 onwards Summary: Whenever you create a PcVue multi-station project, you logically want to display real-time information from all stations in a dedicated view. For […]
[KB1214] PcVue Automatic Deployment
Applies to: PcVue 16.2 onwards Summary: How to install or update PcVue on a complete architecture in a more efficient way? This article describes the procedure to automatize the deployment […]
[KB1205] Migrating a PcVue project containing LON communication
Applies to: PcVue 15 onwards Summary: Prerequisites for migrating a PcVue project containing LON communication. Details: Prerequisites to take into account: – Plan for updating the LON license (LON server […]
[KB1197] Security Alerts
Despite the strict methods and precautions employed when designing, developing and packaging our products, security vulnerabilities may occur. This page lists all known security alerts on products designed by ARC […]
[KB1172] SQLite Provider – Installation tutorial
Applies to: PcVue 16 Summary: SQLite is probably one of the most used database engine. But SQLite editor does no more share installer (.msi).However it is possible to […]
[KB1213] PcVue as a Service – Open Application Explorer
Applies to: PcVue 11.2 onwards Summary: Since PcVue is able to run as a Windows service the use of options in AIExplorer command line becomes very useful. We will describe […]
[KB1203] CPU at 100% with in web Navigator using Webvue in a VM
Applies to: PcVue 16 onwards Summary: With PcVue 16, WebVue uses WebGL technologie. By default, WebVue tries to refresh the whole WebGL view at the refresh rate of the screen, […]
[KB1202] How to disable the native menu in WebVue
Applies to: PcVue 16 (Not included in V15.2.6, but should be available in the next uptdate) Summary: This article aims to show how to disable the native menu in WebVue: Details: […]
[KB1201] Could not load type ‘System.ServiceModel.Activation.HttpModule’ from assembly
Applies to: WebVue, Web Services using IIS Symptom: While trying to access WebVue, or a PcVue Web Services page, or testing web functionalities with the SvWebDiag tool, this error appears: […]
[KB1194] How to create an Exprv.dat file with the Application Architect
Applies to: PcVue 12 onwards Summary: This article explains how to create an Exprv.dat or another file with the Application Architect. Details: In the following example, the expressions are used to […]
[KB1193] JSON provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider allows interaction between JSON files and PcVue. Status: This provider has the status: Release […]
[KB1192] Excel provider – Version 1
Applies to: PcVue 15.2 onwards Summary: This article contains attached files at the end. This provider allows interaction between Excel files and PcVue. Status: This provider has the status: Release […]
[KB1191] Cosmos DB Provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider will allow direct interaction with the NoSQL database engine provided by Microsoft in SaaS […]
[KB1190] WebVue good practices
Applies to:PcVue 12, 15 and 16 Summary:This article aims to provide some best practices for the deployment of WebVue. Everything in this article, from the introduction to the end is […]
[KB1187] PcVue 16 – Extra Documentation
Applies to: PcVue 16 This article was last updated to include information related to PcVue 16.0.0. Summary: This article contains the extra documentation supplied with PcVue 16. Details: Note: These […]
[KB1186] PcVue 16 – Libraries and Demonstration projects
Applies to: PcVue 16 Summary: This article contains the pre-defined libraries and demonstration projects supplied with PcVue 16 in English, French, Russian and Chinese language. If you wish to use […]
[KB1183] REST provider – Version 1
Applies to: PcVue 16 onwards Summary: This article contains attached files at the end. This provider allows direct interaction with a multitude of REST API. Note that some APIs do […]
[KB1184] PcVue 16 – Release Information
Applies to: PcVue 16 This article was last updated to include information related to PcVue 16.2.0. Summary: This article contains the so-called “readme first” information for PcVue 16. Files attached […]
[KB814] CopyField error in the Event Viewer
Applies to: All versions of PcVue, before 11.1 Update 55 Summary: Error in the Event Viewer similar to “CopyField… size of the string is to large…” Details: The appearance of […]
[KB808] PcVue & Active Directory – Account name or password incorrect
Applies to: PcVue 11.0 and later. Summary: Unable to login to PcVue using Active Directory credentials when using Windows Server 2008 R2, Windows Server 2012 R2 or running in a […]
[KB714] Scheduler Runtime Trace
Applies to: PcVue 10.0 sp2 update and later, 11.1 and later. (NOT in 11.0.) Summary: How to activate and interpret the Scheduler trace. Details: How to activate Use the SCADA […]
[KB567] Recipes M9098 message
Applies to: PcVue version 9.0 and earlier. Summary: M9098 message from recipe configuration Details: If, while configuring a recipe, a dialog appears with the message M9098 it means that you […]
[KB437] “Copyfield was x max y” in the event viewer
Applies to: PcVue all versions Summary: Error message “Copyfield was X max Y” in the event viewer Details: This message may appear in the following cases : When you try to […]
[KB336] Estimating the bandwidth used by PcVue Multi station communication
Applies to: PcVue all versions. Summary: Estimating the bandwidth used by PcVue Multi station communication Details: Counters in Audit files Two new counters have been added in Audit files (from […]
[KB341] “Var::SetWatchAtLaunch, Invalid Value” in the event viewer in version 8.10
Applies to: PcVue versions 8.10.The basic content of this article may also be applicable to other versions of PcVue although the detail may vary. Summary: Error message “Var::SetWatchAtLaunch, Invalid Value” […]
[KB219] Warning message about expressions in the PcVue Event Viewer
Applies to: PcVue all versions. Summary: This article explains the error message “Depexpr.dat …” in the Event Viewer and describes how to avoid the problem. Details: The message: Depexpr.dat, line […]
[KB207] Error messages: 16796 and 16797 OPC proxy DLL not registered
Applies to: PcVue version 6.10c onwards. Summary: This article explains how to deal with error messages 16796 and 16797. Details: French PcVue: “OPC,Connexion,%s,La DLL proxy OPC n’est pas enregistree”English PcVue: […]
[KB206] Error messages: 16794 and 16795 DCOM library not installed
Applies to: PcVue version 6.10c onwards. Summary: This article explains how to deal with error messages 16794 and 16795. Details: French PcVue: “Connexion,%s,La librairie DCOM n’est pas installee”English PcVue: “Connection,%s,The […]
[KB201] Error messages 16762 to 16765: Connection lost, connection established
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16762 to 16765. Details: Error Message: Connection, %s, connection lost French PcVue: “16762, OPC, Connexion, […]
[KB202] Error messages 16776 and 16777: Connection, %s, invalid synchronization mode
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16776 and 16777. Details: French PcVue: “16776,OPC, Connexion, %s, mode de synchronisation invalide”English PcVue: “16777, […]
[KB203] Error messages: 16788 and 16789 Unknown server CLSID
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16788 and 16789. Details: French PcVue: “OPC,Creation,%s,Le CLSID du serveur est inconnu”English PcVue: “OPC,Create,%s,Unknown server […]
[KB204] Error messages: 16790 and 16791 Invalid server CLSID (%sh)
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16790 and 16791. Details: French PcVue: “Connexion,%s,Le CLSID du serveur est invalide (%sh)”English PcVue: “Connection,%s,Invalid […]
[KB205] Error messages: 16792 and 16793 connection to server failed (%sh)
Applies to: PcVue version 6.10c onwards. Summary: This article explains how to deal with error messages 16792 and 16793. Details: French PCVUE: “OPC,Connexion,%s,La connexion au serveur a echouee (%sh)”English PCVUE: […]
[KB196] Messages 16750 and 16751: Create, %s, The OPC group is not defined
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16750 and 16751. Details: French PcVue: “16750, OPC, Création, %s, Le groupe OPC n’est pas […]
[KB197] Messages 16752 and 16753: Create, %s, The OPC server is not defined
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16752 and 16753. Details: French PcVue: “16752, OPC, Création, %s, Le serveur OPC n’est pas […]
[KB198] Messages 16754 and 16755: Create, %s, The OPC server is not in the registry
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16754 and 16755. Details: French PcVue: “16754, OPC, Création, %s, Le serveur OPC n’est pas […]
[KB199] Error messages 16756 and 16757: Connection, %s, Failed to connect
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16756 and 16757. Details: French PcVue: “16756, OPC, Connexion, %s, Echec lors de la connexion”English […]
[KB200] Error messages 16760 and 16761: Connection, %s, Failed to connect %s registry
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16760 and 16761. Details: French PcVue: “16760, OPC, Connexion, %s, Impossible de connecter la base […]
[KB194] Messages 16724 and 16725: Create, %s, No write rights on OPC item
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16724 and 16725. Details: French PcVue: “16724, OPC, Création, %s, Pas de droits d’écriture sur […]
[KB195] Messages 16748 and 16749: Create, %s, OPC item is empty
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16748 and 16749. Details: French PcVue: “16748, OPC, Création, %s, L’élément OPC n’est pas renseigné”English […]
[KB185] Messages 16718 and 16719: Write, %s, not connected OPC group
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16718 and 16719. Details: French PcVue: “16718, OPC, Ecriture, %s, Groupe OPC non connecté”English PcVue: […]
[KB186] Messages 16720 and 16721: Write, %s, Error while converting value
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16720 and 16721. Details: French PcVue: “16720, OPC, Ecriture, %s, Erreur lors de la conversion”English […]
[KB187] Messages 16722 and 16723: Create, %s, OPC item type incoherence
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16722 and 16723. Details: French PcVue: “16722, OPC, Création, %s, Possibilité d’incohérence de type avec […]
[KB188] Messages 16726 and 16727: Create, %s, Not Spported OPC Item Type, (%s)
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16726 and 16727. Details: French PcVue: “16726, OPC, Création, %s, Type d’élément OPC non-supporté, (%s)”English […]
[KB189] Error Messages 16730 to 16735
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16730 to 16735. Details: Error messages 16730 and 16731: Create %s Failed to connect OPC […]
[KB190] Messages 16738 and 16739: Notification, %s, OPC Server …
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16738 and 16739. Details: French PcVue: “16738, OPC, Notification, %s, Le serveur OPC ne supporte […]
[KB180] Messages 16700 to 16705: Error while (type) converting on %s
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16700 to 16705. Details: French PcVue : “16700, OPC, erreur sur conversion LOG sur %s”“16702, […]
[KB191] Messages 16740 to 16743: OPC server does not support reads/writes
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16740 to 16743. Details: Error Messages 16740 and 16741: Write, %s, The OPC server doesn’t […]
[KB181] Messages 16708 and 16709: Write, %s, no write rights on OPC item
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16708 and 16709. Details: French PcVue: “16708, OPC, Ecriture, %s, Pas de droits d’écriture sur […]
[KB192] Messages 16744 and 16745: Read, %s, Failed (%sh)
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16744 and 16745. Details: French PcVue: “16744, OPC, Lecture, %s, Echec (%sh)”English PcVue: “16745, OPC,Read […]
[KB182] Messages 16710 and 16711: Write, %s, Failed (%sh)
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16710 and 16711. Details: French PcVue: “16710, OPC, Ecriture, %s, Echec (%sh)”English PcVue: “16711, OPC, […]
[KB193] Messages 16746 and 16747: Create, %s, Link is already used
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16746 and 16747. Details: French PcVue: “16746, OPC, Création, %s, le lien sur %s est […]
[KB183] Messages 16712 and 16713: Write, %s, value out of range
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16712 and 16713. Details: French PcVue: “16712, OPC, Ecriture, %s, Valeur hors limite”English PcVue: “16713, […]
[KB184] Messages 16714 and 16715: Write, %s, No linked OPC Item
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 16714 and 16715. Details: French PcVue: “16714, OPC, Ecriture, %s, Pas d’élément OPC associé”English PcVue: […]
[KB175] Errors 8232, 8233, 14002 and 14003: Connection Error …
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 8232, 8233, 14002 and 14003. Details: French PcVue: “8232, %s: Erreur de connexion. Utilisez la […]
[KB176] Errors 8234, 8235, 14004 and 14005: Connection Error …
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 8234, 8235, 14004 and 14005. Details: French PcVue: “8234, %s: Erreur de connexion. Utilisez la […]
[KB177] Error message 9014: Associated text missing
Applies to: PcVue 7.00h onwards. Summary: This article describes how to deal with error message 9014: “Associated text is?” relating to the back-up configuration dialog box for data archive units. […]
[KB178] Errors 14006 and 14007: Error Creating Table
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 14006 and 14007. Details: French PcVue : 14006, %s : Erreur création table %sEnglish PcVue […]
[KB179] Errors 14054 and 14055: Connection error. Use SVDODBC.DLL
Applies to: PcVue all versions.This article contains obsolete references. Summary: This article explains how to deal with error messages Details: French PcVue: “14054,%s: Erreur de connexion. Utilisez la dll SVDODBC.”English […]
[KB171] Messages 5244 and 5245: INCLUDE.DAT mode
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 5244 and 5245. Details: French PcVue: “5244, Mode INCLUDE.DAT”English PcVue: “5245, INCLUDE.DAT mode” Explanation For […]
[KB172] Errors 5280 and 5281: Applicom Local Database Addresses Overlapping
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 5280 and 5281. Details: French PcVue: “5280, CW, Chevauchement d’adresses dans la Database locale pour […]
[KB173] Errors 8010 and 8011: Unknown Trend Tagname Error
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 8010 and 8011. Details: French PcVue: “8010, Erreur tagname tendance inconnu (%s)”English PcVue: “8011, Unknown […]
[KB174] Errors 8230, 8231, 14000 and 14001: Connection Error
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 8230, 8231, 14000 and 14001. Details: French PcVue: “8230, %s: Erreur de connexion 14000, %s: […]
[KB166] Errors 14 and 15: process %s is missing
Applies to: PcVue all versions. Summary: This article gives information about error messages 14 and 15. Details: French PcVue: “14, Le process %s est absent”English PcVue: “15, Process %s is […]
[KB167] Errors 44 and 45: list full %s
Applies to: PcVue all versions. Summary: This article explains how to deal with the List Full error message. Details:French PcVue: “44, Liste pleine %s” English PcVue: “45, List full %s” […]
[KB168] Errors 62 and 63: Queue full: function %s
Applies to: PcVue all versions. Summary: This article gives information about error messages 62 and 63. Details:French PcVue: “62, File pleine: fonction %s”; English PcVue: “63, Queue full: function %s” […]
[KB169] Errors 172 and 173: Message ignored: %s
Applies to: PcVue all versions. Summary: This article explains how to deal with error messages 172 and 173. Details: French PcVue: “172, Message ignored: %s”English PcVue: “173, Message ignored: %s” […]
[KB170] Errors 300 to 309, WATCHDOG
Applies to: PcVue all versions. Summary: This article explains how to deal with WATCHDOG error messages. Details: Error 300 and 301: Watchdog, No response from process %s French PcVue: “300, […]
- 1
- 2