


Configuration environment
Alarms
Audit and diagnostic
Communication interfaces
Configuration environment
Data acquisition
DataVue/Data Export
Development kits
General
Historical data
HMI
Known issues
Other Products
PcVue installation
PcVue miscellaneous
Real time data
Sample projects
Scripting
Security bulletin
SnapVue
System
TouchVue
UDC
Upgrade issues
Useful tools
Version Information
WebVue
[KB1132] Troubleshooting SG BACnet
When using the Smart Genrator BACnet, sometimes, after selecting the EDE file, the following dialog appears : The first reason explained is about the csv-delimiter used in the EDE file. […]
[KB1231] Error loading the Application Architect configuration
This type of message appears when there are inconsistencies in the project configuration. An error message is systematically displayed in the event viewer: The error indicates the blocking point for […]
[KB1194] How to create an Exprv.dat file with the Application Architect
Applies to: PcVue 12 onwards Summary: This article explains how to create an Exprv.dat or another file with the Application Architect. Details: In the following example, the expressions are used to […]
[KB1139] Impossible to see the Scada Basic editor
Applies to: PcVue 10 onwards Symptom: On a working project we add a new screen, then after some modifications the following problem may appear:– The Scada Basic editor is not […]
[KB1126] Looking for generic import syntax
Applies to: PcVue 12 onwards Summary: In order to get the xml property syntax, there is a simple trick you can activate. Once done, you can select any objects in […]
[KB1122] Automatically position symbols with the Application Architect
Applies to: PcVue 12.0 onwards Summary: Using expressions in the Application Architect allows you to automatically position symbols in a mimic. There are several ways to achieve this, we propose […]
[KB1121] Impossible to see the Variable selector
Applies to: PcVue 10 to PcVue 12 Symptom: On a working project we add a new screen, then after some modifications the following problems may appear:– The variable selector opened […]
[KB1113] Childcount use case in Application Architect
Applies to: PcVue 12 onwards Summary: In Application Architect expression engine, it is possible to count things like the number of templates that has been instantiated at a certain level […]
[KB1101] Device from Ede file is not displayed
Applies to: All PcVue version. Symptom: After importing an EDE File, PcVue does not give the possibility to add a device. The device is not displayed in the list. Details: […]
[KB860] COMPATIBILITY OF PROJECTS USING THE ARCHITECT AND PCVUE 10.0
Applies to: PcVue 10.0 and later Summary: This article affects Application Architect templates saved in local libraries contained in the project’s LIB folder. The syntax used for object names changed […]
[KB800] Outline procedure to edit the Variables Tree configuration file (VAREXP.DAT) using Excel
Applies to: PcVue all versions Summary: The Variables Tree configuration is saved in the CSV (comma separated file) file VAREXP.DAT. With care, it is possible to manage this file directly […]
[KB764] Expression engine rationalisation
Applies to: PcVue 11.1 onwards Summary: The introduction of the Application Architect in PcVue 10.0 brought a richer syntax for expression calculations. In an effort to rationalize elements of syntax […]
[KB715] Reading a string from a PLC
Applies to: PcVue all versions Summary: How to read strings from a PLC (example for Modbus TCP/IP). Details: To read strings from a PLC, the frame format has to be […]
[KB698] Configuring a cyclic action for fractional seconds
Applies to: All PcVue versions (including version 11) Summary: How to configure a cyclic action for fractional seconds. Originator: AK Details: When configuring a cyclic action in the Application Explorer the […]
[KB632] How to import an XML configuration file
Applies to: PcVue version 10.0 onwards. Summary: The XML import provides a standard (vendor-independent) way of supplying configuration data to PcVue. The structure of the XML file and a list […]
[KB627] How to configure mapping using Application Architect
Applies to: PcVue version 10.0 SP1 onwards. Summary: How to map equipment variables with the Application Architect by calculating properties on condition. The appropriate syntax is explained in this article. […]
[KB595] Compatibility of projects developed with PcVue 10.0 and the Architect
Applies to: PcVue version 10.0 onwards Summary: Projects developed with PcVue 10.0 and the Application Architect (AA), and using the Project Library, require a modification before they will run in […]
[KB577] WAGO DALI configuration tool
Applies to: PcVue version 9.0 onwards Summary: This article explains what must be done using the WAGO DALI Tool in order to modify properly addresses or mapping configuration. DALI stands […]
[KB513] Error : Recursive property not allowed
Applies to: PcVue version 10.0.The basic content of this article may also be applicable to other versions of PcVue although the detail may vary. Symptom: Application Architect – ERROR : […]
[KB360] Maximum number of variables in a recipe
Applies to: PcVue version 9.0 onwards. Summary: Since PcVue version 9.0, the maximum number of variables in a recipe can be configured via the menu Configure.Project.General operations.Recipes. Details: The maximum […]
[KB78] Unity versions for Smart Generator
Applies to: PcVue 8.00 onwards.While the basic content of this article remains valid, details may have changed since it was written. Summary: This article defines the versions of Unity that […]