


Browse articles by category
-
Alarms
-
Audit and diagnostic
-
Communication interfaces
-
Configuration environment
-
Data acquisition
-
DataVue/Data Export
-
Development kits
-
General
-
Historical data
-
HMI
-
Known issues
-
Other Products
-
PcVue installation
-
PcVue miscellaneous
-
Real time data
-
Sample projects
-
Scripting
-
Security bulletin
-
SnapVue
-
System
-
TouchVue
-
UDC
-
Upgrade issues
-
Useful tools
-
Version Information
-
WebVue
Alarms
Audit and diagnostic
Communication interfaces
Configuration environment
Data acquisition
DataVue/Data Export
Development kits
General
Historical data
HMI
Known issues
Other Products
PcVue installation
PcVue miscellaneous
Real time data
Sample projects
Scripting
Security bulletin
SnapVue
System
TouchVue
UDC
Upgrade issues
Useful tools
Version Information
WebVue
[KB333] How to include/exclude configuration files in the varexp.dat file?
Applies to: PcVue version 8.10 onwards Summary: Since PcVue version 8.10, it has not been possible include additional configuration files in the Varexp.dat file. When creating a new project all […]
[KB332] Compatibility of Sentinel SuperPro XM and PcVue
Applies to: PcVue all versions. Summary: As from PcVue 8.10 a new protection key, the Sentinel SuperPro XM, is used. Details: For security reasons, as from PcVue 8.10 a new […]
[KB331] Installation error: 9.0 Log Files
Applies to:PcVue version 9.0. Summary:Installation error: 9.0 log files Details:This list is not exhaustive. Log files after 9.0 SP1 installation The files are created in the temporary folder associated with […]
[KB330] Installation error : 8.10 Log Files
Applies to: PcVue version 8.10. Summary: Installation error: 8.10 Log files Details: Log files after 8.10 installation %Temp% = user temporary directory %Disk1Target% = %Program Files%\InstallShield Installation Information\<GUID> pour la […]
[KB329] Installation error: 8.00 Log Files
Applies to: PcVue version 8.00. Summary: Installation error: 8.00 log files Details: In TEMP folder Main 800Inst.log from Setup.exe .NET DotNetfxMsi.log from dotnetfx.exe DotNetFx.log from dotnetfx.exe LangPackMsiXXX.log from msi du […]
[KB328] SQL Server Firewall
Applies to: SQL Server 2005 This article contains obsolete references. Summary: By default ports and used protocols are: SQL Server uses the port 1433 ( TCP) SQL Browser uses the […]
[KB327] Enable the SQL Server Browser service
Applies to: SQL Server 2005 Summary: To facilitate the configuration of the posts, the SQL Server browser allows the discovery on the network of the SQL Server and the offer […]
[KB326] Troubleshooting WebVue and WST issues on Windows Server 2003
Applies to:WebVue versions supplied with PcVue version 11.2 and earlier. WebVue versions supplied with PcVue version 12 onwards use different technology to which this article is not applicable. This article […]
[KB325] What do the EventNumber, VarType and AlarmState columns mean ?
Applies to: PcVue all versions. Summary: The meaning of the EventNumber, VarType and AlarmState columns in an SQL database as used by the Historic Data Server (HDS). Details: Sometimes it […]
[KB324] How to add scrollbars to the Web browser used to display WebVue
Applies to: WebVue versions supplied with PcVue version 11.2 and earlier. WebVue versions supplied with PcVue version 12 onwards use different technology to which this article is not applicable. Summary: […]
[KB323] WebScheduler FAQ
Contents : How do I force my web browser to use a different default language that is used by Web Scheduler than the one set in the operating system? For […]
[KB321] VBA function DoEvent
Applies to: PcVue all versions. Summary: This article describes how to use the VBA function DoEvents and warns about the possible problems that can occur when using it. Details: The […]
[KB320] When not to use SCADA Basic SYSTEM mode SYSTEM
Applies to: PcVue version 8.00 onwards. Summary: Do not use SYSTEM mode SYSTEM to launch a batch file which takes a long time to execute. For example a batch launching […]
[KB319] User cannot change his password
Applies to: PcVue versions 8.00 and 8.10. Summary: The User Rights are in Advanced Security Strategy mode (21CFR11). You are administrator and you create a new user. Then you log […]
[KB318] UIVConf.dat file description
Applies to: PcVue. See version information below. Summary: UIVConf.dat file description Details: Default UIVConf look like this: [WatchGroup] RateUpdate=0 [Expression] MaxNumber=50000 [EventActions] MaxNumber=32000 [WatchGroup] RateUpdate is the rate at which […]
[KB316] Applicom – S7/xxx-2DP with S7 or DP messaging
Applies to: Applicom. Summary: Technical information to help with the configuration of an S7 PLC such as S7/315–2DP with an embeded profibus DP port on the CPU. Details: See attached […]
[KB314] SVSQL mode CONNECT – Return Code: 0
Applies to: PcVue all versions. Summary: The SCADA Basic instruction, SVSQL mode CONNECT, return code 0 is not documented in the online help. The online help describes the verb “CONNECT […]
[KB313] How to restart a PcVue project – svrestart.exe
Applies to: PcVue version 7.00 onwards Summary: This article describes how to restart a PcVue project by using the executable “SvRestart.exe”.An attached project, made with version 8.2 of […]
[KB312] SQL Server 2008 Unnamed Instance
Applies to:SQL Server 2008. Summary:It is not possible to create a database with SQL server 2008, installed as unnamed instance, when using generic syntax “.\”. This syntax, which allows access […]
[KB311] Sql Server 2005 Express installation problem with MSXML SP2 on XP
Applies to: SQL Server 2005 and Windows XP Summary: SqlServer setup fails: SqlServer setup does not complain about missing prerequisites but is unable to install MSXML extensions and the MS […]
[KB310] Setting MTU Size on PC for client site VPN
Applies to: PcVue all versions. Summary: Solution for a multi station problem due to VPN using the software SetMTU.exe to configure properly Windows. Solution: The issue was a disconnection between […]
[KB309] Sentinel protection installation: Minimum requirements for PcVue when using an USB dongle
Applies to: PcVue versions 8.00, 8.10 and 8.2. Summary: This article describes: What is installed from Sentinel Safenet software, with standard PcVue installation Known issues about sentinel driver installation and […]
[KB308] Sentinel driver issue at Windows startup
Applies to: PcVue versions with support for Windows XP and Server 2003. Summary: How to load Sentinel driver at Windows startup Details: When you want to start PcVue at Windows […]
[KB307] Dream Report Info – Securing the Web features using https
Applies to: PcVue all versions. Summary: Context How Dream Report fits with secured network environments, in particular for web access based on HTTPS. Dream Report is involved in HTTP security […]
[KB306] SCADA Basic function execution from VBA
Applies to: PcVue all versions. Summary: By forcing a variable in VBA code you can trigger a SCADA Basic function. By forcing a variable in SCADA Basic you can trigger […]
[KB305] Replication sample with 2 SQL Express and 1 SQL Standard
Applies to: PcVue all versions with support for SQL Server 2005.The basic content of this article may also be applicable to other versions of Pcvue and SQL Server although the […]
[KB304] Remote License errors
Applies to: PcVue all versions. Summary: While trying to update a licence key using the Remote License Manager the following errors may appear. Details: Error 3 – Key not detected […]
[KB303] Remote Desktop Connexion
Applies to: PcVue all versions with support for Windows XP SP3, Windows Vista and Windows Server 2008. Summary: The /console option does not work for mstsc. Details: Problem: Since Version […]
[KB302] A solution to redundant on-line printing in PcVue
Applies to: PcVue version 7.20d SP3 onwards. Summary: This document is intended for providing a solution to redundant on-line printing using PcVue. The architecture in a schema is first given […]
[KB301] Applicom – OPC Redundancy (only available from V3.6.0, all cards & messaging)
Applies to: PcVue all versions. Summary: You need to change the target device during the process . Use OPC redundancy (swap.ini file & EQU_CHANGE item). Details: Benefits: 1srt OPC Server […]
[KB300] Queue regulation
Applies to: PcVue version 9.0.The basic content of this article may also be applicable to later versions of PcVue although the detail may vary. Summary: This article describes how […]
[KB299] Display time stamped and quality of a variable using a standard animation
Applies to: PcVue all versions. Summary: How to display time stamped and quality of a variable using a standard animation Details: To display the time stamp of a variable you […]
[KB297] OPC SERVER CONFIGURATION
Applies to: PcVue 8.2 SP2 and 9.0. The basic content of this article may also be applicable to later versions of PcVue although the detail may vary. Summary: This document […]
[KB296] Network station performance
Applies to: PcVue all versions.While the basic content of this article remains valid, details may have changed since it was written. Summary: Bandwidth use in network station configuration and optimization. […]
[KB295] NetDDE problems when using Windows XP
Applies to: PcVue all versions supporting Windows XPThis article contains obsolete references. Summary: NetDDE problems when using Windows XP. Details: Connection timeout is always triggered before having an acknowledgment from […]
[KB294] Modify a text attribute of a variable using a standard animation
Applies to: PcVue all versions. Summary: Modify a text attribute of a variable using a standard animation. Details: To modify a variable’s extended text attribute, you can use a simple […]
[KB293] Modbus TCPIP Protocols Block Length
Applies to: PcVue all versions. Summary: Modbus TCP/IP Protocols (Additional information) Details: The CIMWAY protocols Open Modbus Master and Open Modbus Slave support block size lengths that may exceed the […]
[KB292] Modbus IP and Network Behaviour
Applies to: PcVue all versions. Summary: Using Modbus IP, in network architecture, its possible for the client station to unexpectedly communicate directly with equipment. How? A variable is incorrectly configured […]
[KB290] Max number of points displayed in a trend viewer
Applies to: PcVue all versions. Summary: Maximum number of points displayed in a Trend Viewer Details: PcVue is limited to 4000 points on an historical request (one request per trace […]
[KB289] Install DataVue on windows 7.doc
Applies to: DataVue and Windows 7This article contains obsolete references. Summary: Version 2.76 of DataVue is not qualified to work on Windows 7. However it can be used in the […]
[KB288] Increase the number of Webvue client connection under XP
Applies to: WebVue versions supplied with PcVue version 11.2 and earlier and supporting Windows XP. WebVue versions supplied with PcVue version 12 onwards use different technology to which this article […]
[KB287] How to stop Dream Report from PcVue
Applies to:PcVue all versions. Summary:How to stop the Dream Report run time from PcVue. Details:Create a batch file in the system directory of Dream Report with this content: drt.exe -shut […]
[KB286] How to reverse a bit coming from PLC
Applies to: PcVue all versions. Summary: Some PLC programs use some bits in “Inverse logic”. We need to invert them for PcVue. Details: PcVue can do it automatically – but […]
[KB284] How to mask PcVue Main window
Applies to: PcVue version 8.2 onwards. Summary: How to hide the PcVue main window (workspace). Details: This is a sample project which explain how to hide / show the PcVue […]
[KB283] How to have the same time on all Stations
Applies to: PcVue all versions with support for Windows 2000, XP and NT. Summary: How to have the same time on all stations Details: Here a DOS command to have […]
[KB282] How to display 3D models from SolidWorks in PcVue
Applies to: PcVue all versions. Summary: PcVue is unable to use 3D images in SolidWorks native format. Details: One solution is to convert 3D SolidWorks models to the VRML format […]
[KB281] How to fix some graphics behaviour issues
Applies to: PcVue all versions.This article contains obsolete references. Summary: How to fix some graphics behaviour issues, like : BMP pictures become black on mouseover Colour of a text displayed […]
[KB280] How to display milliseconds in a Trend Viewer
Applies to: PcVue all versions. Summary: How to display milliseconds in a Trend Viewer Details: For displaying, milliseconds in time information and in cursor mode in trend viewer, you have […]
[KB279] How to broadcast exception periods from one time table to others
Applies to: Pcvue version 8.2 SP1 onwards. While the basic content of this article remains valid, details may have changed since it was written. Summary: How to broadcast exception periods […]
[KB278] How to correctly configure the Single Axis Position animation to create a slider control
Applies to: PcVue all versions. Summary: How to correctly configure the Single Axis Position animation to create a slider control Details: The Single Axis Positioning animation can be used to […]