[KB1255] Repeat Query for Sql variables
We have a query execution defined to be repeated every 10 seconds and with a maximum received row count equal to 100: Then in the query itself, we add conditions […]
[KB1237] Adding a Development station to a Multi-station Architecture
The DEV station remains passive under normal conditions but can be temporarily activated for testing purposes. Here are the steps to add a DEV station to a multi-station architecture: Configuration: […]
[KB1205] Migrating a PcVue project containing LON communication
Applies to: PcVue 15 onwards Summary: Prerequisites for migrating a PcVue project containing LON communication. Details: Prerequisites to take into account: – Plan for updating the LON license (LON server […]
[KB1158] Smart Generator With TIA Portal
Applies to: PcVue 11.2 onwards Summary: If you need to generate variables from TIA Portal using Smart Generator you need to follow this steps Details: This first version allows importing […]
[KB1149] Register LonWorks catalogs
Applies to: PcVue 15 onwards Summary: Problem when declaring a new LON node: If after installing version of IZOT Net Server and PcVue, you are unable to declare a new LON node […]
[KB1106] Version and Compatibility of LonWorks software
Applies to:PcVue and LonWorks Summary:Information about different version and compatibility of LonWorks software, regarding PcVue version and also regarding Windows version. Details:To do a Lon configuration, you need a server […]
[KB1101] Device from Ede file is not displayed
Applies to: All PcVue version. Symptom: After importing an EDE File, PcVue does not give the possibility to add a device. The device is not displayed in the list. Details: […]
[KB1093] Configure IZOT CT with PcVue
Applies to: PcVue 15.0 onwards Summary: This article explain the differents steps to configure a LON project using IzoT and PcVue. Required hardware : – 1 LIP : Router – […]
[KB1092] Configure NL220 with PcVue
Applies to: PcVue 11 Onwards Summary: This article explain the differents steps to configure a LON project using NL220 and PcVue. Required hardware:– 1 LIP : Router– PcVue 11 onwards […]
[KB1073] LoRaWAN Multitech Gateway
Applies to:PcVue version 12 onwards (LoRaWAN reading) PcVue version 15 onwards (LoRaWAN writing) Summary:This article gives all the information and files needed to connect to the Multitech(MultiConnect Conduit) LoRaWAN gateway. […]
[KB1070] LoRaWAN Kerlink Gateway
Applies to: PcVue version 12 onwards (LoRaWAN reading) PcVue version 15 onwards (LoRaWAN writing) Summary: This article gives all the information and files needed to connect to the Kerlink (Wirnet […]
[KB1037] Using Telnet to validate a socket
Applies to: PcVue all versions. Summary: This article explains how to validate a TCP/IP socket on a specific port using telnet. If the ping works but you still got problem […]
[KB1014] Labels for Adeunis TIC
Applies To: PcVue version 12 onwards Adeunis IoT Configurator 1.4.1 Summary: Find a movie to add to know TIC label. TIC is an Adeunis device to display the electric […]
[KB1013] LoRaWAN driver
Applies to: PcVue version 12 onwards. Summary: This article give all the information and files needed to connect to the Multitech LoRaWAN gateway. Please refer to the .pdf documentation attached for […]
[KB1007] IEC 61850 – How to send a control (to finish)
Applies to: PcVue 10.0 onwards Summary: This article describes the way to configure a controllable variable Details: A controllable logical node will contain the specific functional constraint “CO”.This functional constraint […]
[KB1006] Connect to an Adeunis IoT device
Summary: Find a movie to add and connect an Adeunis IoT device in PcVue. PcVue version 12 onwards. Find a movie to add device in Application Architect with the Adeunis […]
[KB1005] Change battery in Adeunis device
Summary: Find a movie to focus on the replace battery. Find a movie to manipulate a magnet and battery.
[KB1004] Do a join and wake up Adeunis Device
Summary: Find a movie to focus on the join between an Adeunis IoT device and Multitech Gateway. Find a movie to manipulate a magnet and the IoT device if […]
[KB1003] Connect to the webrowser Multitech Gateway
Applies to minimum: PcVue 12 Multitech Conduit firmware 1.6.4 Summary: This article explains how to connect to the Multitech Webbrowser Details: To access to the web interface Multitech gateway, follow differents […]
[KB874] LEGACY DATA ACQUISITION DRIVERS
Summary: The following protocols were inherited from earlier versions of the Supervisor. Many have been validated for use with this version and are in regular use. However, before using one […]
[KB848] BACnet System Variables
Applies to: PcVue 11.2 only Summary: The method used for BACnet connectivity was changed for 11.2. The 11.2 help still contains status variable information for the previous connectivity method. The […]
[KB836] Problem when installing the BDS on Windows Server 2008R2
Applies to: PcVue 11.1 and earlier Summary: Problem when installing the BACnet Data Server on Windows Server 2008R2.Orginator: BO Details: After PcVue installation the the BDS is completely not installed. […]
[KB805] BDS Admin Error Message
Applies to: PcVue 11.1 and earlier Summary: BDS Admin Error Message Details: If you use the Startup Type Automatic for the BACnet DataServer service you may, under some conditions, see […]
[KB804] How to configure Fetch/Write communication for the S7-1500
Applies to: All version of PcVue supporting the Siemens Master driver. Summary: How to configure Fetch/Write communication via a CP1543-1 for the S7-1500. Originator: BO Details: This article shows you […]
[KB781] LonWorks Optimization
Applies to: All PcVue versions with LonWorks communication Summary: The first step to optimize your LonWorks communication Details: 1. In project settings you must ensure that the property Permanent […]
[KB783] Modbus functions used according to frame data type
Applies to: PcVue prior version 16 Summary: This article gives the correspondance between the Modbus Ip function used and the PcVue Frame data type Details: Please find the correspondance table […]
[KB733] Double mapping on a CIMWAY frame
Applies to: PcVue 10.0 SP1, 11.0 onwards Summary: Double mapping on a CIMWAY frame.Originator: EM Details: It is now possible to map two variables to the same item […]
[KB724] SAIA Solution not to install the full PG5 suite
Applies to: Any PcVue version Summary: Making the SAIA driver works without installing PG5 suite Details: In order for the driver SAIA to work it is mentionned in the help […]
[KB688] Windows does not support Net DDE anymore.
Applies to: Windows XP and later. Summary: From Windows XP operating system, there is an uncompatibility issue regarding NetDDE. Details: NetDDE was removed from Windows XP, but was still available […]
[KB684] BACnet – Segmentation feature
Applies to: All PcVue version Summary: This article describes how the segmentation of BACnet messages works and how to manage it with Pcvue. Details: The segmentation is the possibility to […]
[KB679] How to configure Twincat Protocol
Applies to: All PcVue Versions including Twincat Protocol Summary: You will find attached, documentation explaining how to implement Twincat Protocol in PcVue Download attachments: Protocol TwinCATv1.2
[KB656] UCPT and SCPT variables
Applies to: PcVue all versions Summary: his article explains how to read Lonworks UCPT and SCPT tags from an equipment. Details: There are two methods : Using the SCADA verb […]
[KB653] BACnet Port conflict
Applies to: PcVue all versions.The BACnet implementation from PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary: The BACnet protocol, as with other protocols, […]
[KB652] COV limitation
Applies to: PcVue all versions.The BACnet implementation from PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary: Sometimes PcVue can no longer subscribe to […]
[KB651] How to use priority in the PcVue Modbus redundancy
Applies to: PcVue version 10.0 SP1 onwards. Summary: This article describes how to use priority in PcVue Modbus redundancy. PcVue Modbus TCP is able to manage redundancy of up to […]
[KB628] Communication with a Siemens S7-1200/1500
Applies to: PcVue version 10.0.The basic content of this article may also be applicable to other versions of PcVue although the detail may vary. Summary: How to communicate with a […]
[KB625] How to optimize/increase communication speed with a PLC
Applies to: PcVue all versions. Summary: How to improve communication when the status is e000. Details: A communication status of e000 means that frames are being scanned at a slower […]
[KB622] Using a Digi portserver with PcVue
Applies to: PcVue version 10.0.The basic content of this article may also be applicable to other versions of PcVue although the detail may vary. Summary: This article describes the problem […]
[KB602] BACNet Configuration in PcVue
Applies to: PcVue version 10.0 SP1 to version 11.1.The BACnet implementation from PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary: The way in […]
[KB598] BDSAdmin and DEMO MODE
Applies to: From PcVue version 9.0 to 11.1The BACnet implementation from PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary: Why is the BdsAdmin […]
[KB584] EDE file structure
Applies to: PcVue version 9.0 SP1 onwards Summary: As there is no standard to define structure of the EDE file, automation manufacturer provides their own EDE files. In some […]
[KB576] Example of communication between remote OPC Client and PcVue
Applies to: PcVue all versions Summary: This article explains how to configure communication between a remote OPC client and PcVue. Details: Context : This configuration has been implemented with two […]
[KB573] Offline configuration with BNDF file
Applies to : PcVue version 9.0 to version 11.1. BACnet communication in PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary : This article […]
[KB559] S7 ISO Error codes
Applies to: PcVue vesion 10.0 only Summary: The error codes, in the help for version 10.0 of PcVue, for the IP ISO S7 protocol are out of date. The following […]
[KB553] BACnet over LonTalk
Applies to: PcVue version 9.0 to version 11.1.BACnet communication in PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary: BACnet devices (equipment), connected via […]
[KB536] Modbus Plus Protocol
Applies to: PcVue version 10.0 (Build 2476) Summary: This article explains how to use Modbus Plus protocol with PcVue 10.0. Details: The Modbus Plus driver is not supplied with PcVue […]
[KB519] BACnet : variables status
Applies to: PcVue version 9.0 onwards.The BACnet implementation from PcVue version 11.2 onwards uses different technology to which this article is not applicable. Summary: You will find below, a reminder […]
[KB456] Lonworks increase limits of Network Variables (Nvs)
Applies to: PcVue version 6.10 onwards. Summary: How to increase the Lonworks limits in the Windows Registry for projects with more than 20000 tags. Details: Run (Windows + R) Windows […]
[KB443] How to connect to Siemens PLC simulator – PLCSim
Applies to: PcVue all versions. This article contains obsolete references. Summary: Link to a tool that allow PcVue to communicate with Siemens PLC simulation tools PLCSim Details: If you want […]
[KB438] Warning about watchdog treatment
Applies to: PcVue all versions Summary: Watchdog treatment configuration. Details: Please note that watchdog treatment MUST ONLY BE USED with EQUIPMENT variables. Using the watchdog treatment with other variable source […]